BWFZN - 0423161, INDIVIDUAL LISTING FOR (SUPDAT)

Product Identification

Product ID:0423161, INDIVIDUAL LISTING FOR (SUPDAT)
MSDS Date:12/08/1992
FSC:6550
NIIN:00N056461
MSDS Number: BWFZN

Responsible Party
BECTON-DICKINSON MICROBIOLOGY SYSTEMS INC
250 SCHILLING CIR
COCKEYSVILLE, MD 21030
US

Emergency Phone: 301-584-7169

Info Phone: 410-584-7154

Cage: 05545

Contractor
BECTON DICKINSON AND CO MICROBIOLOGY SYSTEMS DIV
HUNT VALLEY, MD 21030-1103 US

Telephone: 410-771-0101

Cage: 05545

Ingredients

3-QUINOLINECARBOXYLIC ACID,

CAS: 85721-33-1

RTECS: VB1993800

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THIS PRODUCT CONTAINS NO HAZARDOUS
MATERIAL AS DEFINED BY OSHA HAZARD COMMUNICATION STANDARD. HOWEVER,
IN EVENT OF SPILL OR ACCIDENT INVOLVING THIS MATERIAL, GOOD
PERSONAL HYGIENE SHOULD BE PRACTICED. ALSO, INDIVIDUALS WITH KNOWN
OR SUSPECTED ALLERGIES TO ANTIBIOTICS SHOULD ADVISE MD OF INCIDENT
THAT (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: MAY HAVE RESULTED IN EXPOSURE TO
ANTIBIOTIC TREATED PRODUCT.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH KNOWN OR SUSPECTED
ALLERGIES TO ANTIBIOTICS SHOULD ADVISE MD OF INCIDENT THAT MAY HAVE
RESULTED IN EXPOSURE TO ANTIBIOTIC TREATED PRODUCT.

First Aid

First Aid:INGEST: CALL MD IMMEDIATELY . INHAL: REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION) . EYES:
IMMEDIATELY FLUSH W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK
ASSISTANCE FROM MD . SKIN: FLUSHW/COPIOUS AMOUNTS OF WATER. CALL
MD .

Fire Fighting

Extinguishing Media:IF PRODUCT BECOMES INVOLVED IN A FIRE SITUATION ANY
EXTINGUISHING MEDIA USED DURING FIRE FIGHTING WILL BE COMPATIBLE.
Fire Fighting Procedures:NONE INDICATED. USE NIOSH/MSHA APPROVED SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE INDICATED.

Accidental Release

Spill Release Procedures:MAY BE SWEPT UP AND DISPOSED OF WITH NORMAL
LAB TRASH.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE INDICATED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NOT REQUIRED UNDER NORMAL PRODUCT USAGE. USE
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
.
Ventilation:NOT REQUIRED UNDER NORMAL PRODUCT USAGE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED SAFETY GLASSES .
Other Protective Equipment:NOT REQUIRED UNDER NORMAL PRODUCT USAGE.
Work Hygienic Practices:GOOD PERSONAL HYGIENE SHOULD BE PRACTICED.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: SUSCEPTIBILITY TEST DISCS.

Chemical Properties

Solubility in Water:INSOLUBLE
Appearance and Odor:PAPER DISCS OF VARIABLE COLOR.

Stability

Stability Indicator/Materials to Avoid:YES
NOT DETERMINED.
Stability Condition to Avoid:NOT DETERMINED.
Hazardous Decomposition Products:NOT INDICATED.

Disposal

Waste Disposal Methods:MAY BE DISPOSED OF WITH NORMAL LAB TRASH. FOLLOW
ALL FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.